| Nominal Battery Voltages : | 12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up) |
| Maximum Output Current : | 80 amps @ 104° F (40°C) with adjustable current limit |
| Maximum Solar Array STC Nameplate : | 12 VDC systems 1250 Watts / 24 VDC systems 2500 Watts / 48 VDC systems 5000 Watts / 60 VDC systems 6250 Watts |
| NEC Recommended Solar Array STC Nameplate : | 12 VDC systems 1000 Watts / 24 VDC systems 2000 Watts / 48 VDC systems 4000 Watts / 60 VDC Systems 5000 Watts |
| PV Open Circuit Voltage (VOC) : | 150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum |
| Standby Power Consumption : | Less than 1 Watt typical |
| Power Conversion Efficiency : | 97.5% @ 80 Amps in a 48 VDC System - Typical |
| Charging Regulation : | Five Stages - Bulk, Absorption, Float, Silent and Equalization |
| Voltage Regulation Set points : | 10 to 80 VDC user adjustable with password protection |
| Equalization Charging : | Programmable Voltage Setpoint and Duration - Automatic Termination when completed |
| Battery Temperature Compensation : | Automatic with optional RTS installed / 5.0 mV per °C per 2V battery cell |
| Voltage Step-Down Capability : | Can charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input |
| Programmable Auxilary Control Output : | 12 VDC output signal which can be programmed for different control applications (Maximum of 0.2 amps DC) |
| Status Display : | 3.1" (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total |
| Remote Display and Controller : | Optional Mate or Mate2 with RS232 Serial Communications Port |
| Network Cabeling : | Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires) |
| Data Logging : | Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production |
| Hydro Turbine Applications : | Consult factory for approved Turbines |
| Positive Ground Applications : | Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications) |
| Operating Temperature Range : | Minimum -40° to maximum 60° C (Power capacity of the controller is automatically derated when operated above 40° C) |
| Environmental Rating : | Indoor Type 1 |
| Conduit Knockouts : | One 1" (35mm)on the back; One 1" (35mm) on the left side; Two 1" (35mm) on the bottom |
| Warranty : | Standard 5 year / Available 10 Year |
| Weight - Unit : | 12.20 lbs (5.56 kg) |
| - Shipping : | 15.75 lbs (7.10 kg) |
| Dimensions - Unit : | 16.25"H x 5.75"W x 4"D (41.3 x 14 x 10 cm) |
| - Shipping : | 21"H x 10.5"W x 9.75"D (53 x 27 x 25 cm) |
| Options : | Remote Temperature Sensor (RTS), HUB 4, HUB 10, MATE, MATE 2 |
| Menu Languages : | English & Spanish |